Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batchVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batch
Item number 78-1002648-001

Checklite 250 Plus Kit for microbial biomass analysis and hygiene monitoring for 250 determinations

6.193 SEK

In stock
  • Rapid detection of ATP from biomass, including microbial cells
  • Easy to use
Request a quote 78-1002648-001

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and hygiene tests for self-monitoring since 2003
  • Call us +46 8 753 00 04

Category:

Description

78-1002648-001 Test hygiene > Checklite

The CheckLite 250 Plus is a kit for microbial biomass analysis and hygiene monitoring based on the ATP measurement method. It can detect ATP levels equivalent to more than 10,000 E. coli cells/ml.

It contains thermostable firefly luciferase. The bioluminescence reagent contains firefly luciferin and luciferase. This luciferase enzyme catalyzes the reaction where luminescence is observed due to the interaction between ATP and luciferin. The amount of bioluminescence produced in the reaction is directly proportional to the amount of ATP in the sample.

1 x 250 determinations


Test duration: 20-40 minutes including calibration curve

Storage: 2 – 8 °C, DO NOT FREEZE

Kit contents:

Luciferin-Luciferase reagent – 5 vials with lyophilized powder

Preparation buffer – 5 vials (5.5 ml)

ATP reagent – 5 vials (5.5 ml)


Preparation of bioluminescence reagent

The Luciferin-Luciferase reagent is stored under vacuum in vials marked with green labels.

Pour the reconstitution buffer from the pink-labeled vial into the opened green-labeled vial and let it stand at room temperature for a few minutes (a slight sediment may form in the reconstitution buffer during storage. This does not affect the test results).

Gently swirl the vial until the contents are completely dissolved. Avoid foaming.

Do not touch the edge of the vial or the top of the rubber stopper directly with your hands, as this can sometimes increase the reagent’s baseline value.

One vial of Luciferin-Luciferase reagent can be used for more than 50 analyses under normal conditions.

Sample handling

The ATP concentration in living cells changes rapidly. Therefore, extract ATP from the cells or freeze the cells immediately after sampling. Even during extraction, it may be necessary to inhibit or destroy ATP-degrading enzymes to prevent the enzymes from reducing the ATP concentration.

Sample pre-treatment

Solid samples:

Treat the sample with a stomacher or a homogenizer and use the supernatant for subsequent measurement.

Liquid samples:

If the sample solution is turbid or colored, or contains inhibiting ions such as Cl-, dilute the sample as needed.

Measurement

Transfer 100 µl of the sample, prepared as described above, into a measurement test tube and add 100 µl of the ATP-releasing reagent solution to the test tube.

Allow the test tube to stand at room temperature for 10-60 seconds to extract ATP from the cells. The time required for extraction varies depending on the type of microorganisms. For example, it takes 10-20 seconds to extract ATP from bacterial cells and 60 seconds for yeast cells.

Immediately after extraction, add 100 µl of the Luciferin-Luciferase reagent solution and measure the amount of bioluminescence using a luminometer such as the Lumitester C-110 (ID no. 1 002 647).

To create a calibration curve, measure the amount of bioluminescence of serial dilutions of the ATP standard solution using the method described above.

The number of microbial cells (colony-forming units, CFU) can be determined based on the correlation between the amount of ATP and the number of CFU, previously counted using the conventional colony counting method.

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *