Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batchVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batch
Item number 78-1002650-001

Checklite HS Kit for highly sensitive microbial biomass analysis for 100 determinations

5.491 SEK

In stock
  • Easy to use
  • Fast performance
  • Highly sensitive microbial biomass analysis
  • Detects 1000 cells of coliform bacteria/ml (100 cells/analysis)
  • Contains specially designed ATP-degrading enzymes
Request a quote 78-1002650-001

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and hygiene tests for self-monitoring since 2003
  • Call us +46 8 753 00 04

Category:

Description

78-1002650-001 Test hygiene > Checklite

The CheckLite HS Set is a kit for the analysis of microbial biomass based on the ATP measurement method. It contains thermostable firefly luciferase and ATP-degrading enzymes developed by Kikkoman Corp. The bioluminescence reagent contains firefly luciferin and luciferase. Luciferase reacts specifically with ATP and catalyzes the reaction to produce bioluminescence. This bioluminescence is directly proportional to the amount of ATP in the sample.
All living cells have ATP as an energy source. Therefore, the total cell mass can be determined by measuring the bioluminescence via the luciferase reaction, after extracting ATP from the cells using the ATP-releasing reagent in this kit.

1 x 100 analyses


Test duration: 60-90 minutes (including calibration curve)
Storage: 2-8 °C, DO NOT FREEZE
Kit Composition:
Luciferin-luciferase reagent HS: (2 bottles dark green marked)
Reconstitution buffer
ATP-releasing reagent


ATP-eliminating reagent
Reconstitution buffer for ATP-eliminating reagent; (5.5 ml x 2 vials yellow marked)

The concentration of ATP in living cells changes rapidly. Therefore, extract ATP from cells or freeze the cells immediately after sampling. Even during extraction, it may be necessary to inhibit or destroy ATP-degrading enzymes to prevent the enzymes from reducing the ATP concentration.
Prepare the bioluminescence and ATP-elimination reagents according to the manual. After preparing the samples, mix the reagent and samples to start the reaction.
By measuring the bioluminescence in a luminometer, such as the recommended C-110, the level of ATP can be determined. These results can be quantified by plotting against a prepared standard curve. The number of microbial cells (colony-forming units, CFU) can be obtained based on the correlation between the amount of ATP and the number of CFU counted in advance using the traditional colony counting method.
For more information, see the manual.

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *