Published 14 October 2026 at 02:01
It’s a familiar situation: a bearing on a motor sounds wrong, a fuse cabinet smells burnt, or an oven deviates from its setpoint. You want to know the temperature at that one small spot, but it’s behind a guard, high up, or on a surface too hot to approach. A basic infrared thermometer with poor optics then measures a large area instead of the spot you’re actually interested in, and the average tells you little.
What the RayTemp 38 is
The ETI RayTemp 38 is a pistol-shaped, non-contact thermometer with a measuring range of -59.9 to 999.9 °C. What sets it apart from simpler models is the 50:1 optical ratio. At a distance of 50 cm it measures a spot of about 1 cm, and at two metres about 4 cm. Two laser dots show the size and position of the measuring spot. The instrument also has a socket for a type K thermocouple, so it works as a contact thermometer as well.
The problems it solves
Small targets at a distance are the first. The second is that surfaces have different emissivity. Shiny metal reads lower than matte, and this is a common source of error. Here you can set the emissivity between 0.1 and 1.0 in steps of 0.01, with 0.95 as the default. You can also read max, min, difference and average, and set alarm limits for high and low temperature.
Three areas of use
Maintenance and electrical work. In switchgear and motor rooms you can check connections, contactors and bearings from a safe distance. A spot that is a few degrees warmer than its neighbours often reveals a loose connection or incipient damage before it causes downtime.
Workshop and heat treatment. Around furnaces, mould tools and welded parts, the surface is often hot and the measuring spot small. With 50:1 you can stand at a proper distance and still hit the right spot. Above 200 °C the instrument gives readings with 1 °C resolution, which is sufficient for this type of check.
Food production. You can quickly check the surface temperature of packaging, conveyor belts and hot equipment without contaminating anything. If you need the core temperature, you plug a type K probe into the socket and measure in the product. That gives you two instruments in one handle.
Why it pays off
An instrument that replaces both an IR thermometer and a contact thermometer saves on purchasing, calibration and space in the toolbag. The greater value, however, lies in time. You avoid scaffolding, shutdowns and repeated measurements because you hit the right spot the first time. And when a faulty component is found thermally in good time, it becomes a planned action instead of a breakdown. Automatic shut-off after 60 seconds saves the battery and can be turned off if you want to do longer measurement series.
Always measure with a known emissivity, or put a piece of matte tape on shiny surfaces, so that the results are comparable over time.