Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batchVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batch
Item number 78-1002659-001

Checklite AT100 100 determinations

6.373 SEK

In stock
  • Highly sensitive microbial biomass analysis based on the ATP measurement method
  • No centrifugation required
  • Reduces time and effort for aseptic testing of milk, sour drinks, etc.
  • Easy to use
Request a quote 78-1002659-001

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and hygiene tests for self-monitoring since 2003
  • Call us +46 8 753 00 04

Category:

Description

78-1002659-001 Test hygiene > Checklite

The CheckLite AT100 is a microbial biomass analysis kit based on the ATP measurement method. It is particularly suitable for aseptic testing of acidic beverages and retort food after appropriate incubation. It contains thermostable firefly luciferase and an ATP-eliminating reagent.
Luciferase reacts specifically with ATP, producing a directly proportional amount of bioluminescence. ATP levels due to extracellular ATP from emulsified products, such as milk, cream, and products containing milk, can be several orders of magnitude higher than the ATP levels found in other food products. This high level of ATP interferes with the sensitive detection of intracellular ATP from contaminating microorganisms. With CheckLite AT100, somatic cells and micelle structures are broken down, and the released ATP and any extracellular ATP are degraded to very low concentrations compared to other ATP methods, enabling sensitive detection of bacteria in emulsified product samples.

1 x 100 analyses


Kit composition
Luciferin-luciferase reagent HS – 2 bottles dark green marked
Reconstitution buffer for Luciferin-luciferase reagent – 5.5 ml x 2 vials pale pink marked
ATP reagent – 5.5 ml x 2 plastic bottles light blue marked
ATP-ELIMINATING REAGENT – 2 vials red pink marked
Reconstitution buffer for ATP-eliminating reagent – 5.5 ml x 2 vials yellow marked
Sample dilution buffer – 25 ml x 4 plastic bottles dark blue marked
Sample treatment reagent – 5.5 ml x 2 plastic bottles brown marked


The concentration of ATP in living cells changes rapidly. Therefore, extract ATP from cells or freeze the cells immediately after sampling. Even during extraction, it may be necessary to inhibit or destroy ATP-degrading enzymes to prevent the enzymes from reducing the ATP concentration.
Prepare the bioluminescence and ATP-eliminating reagents according to the manual. After preparation of the samples, mix the reagent and samples to start the reaction.
By measuring the bioluminescence in a luminometer, such as the recommended C-110, the level of ATP can be determined. These results can be quantified by plotting against a prepared standard curve. The number of microbial cells (colony-forming units, CFU) can be obtained based on the correlation between the amount of ATP and the number of CFU counted in advance using the traditional colony counting method.
For more information, see the manual.