Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without Guessing

Legionella Control That Holds Up to Boverket’s Requirements: When the Water Temperature in Your Coffee Mug Determines Whether the System Is Safe

Published 1 July 2026 at 09:55

There are few issues in property management where the consequences of a faulty measurement can be as serious. Legionella bacteria live in water pipes where hot water doesn’t reach above 55 °C and cold water drifts above 20 °C. An infected person can develop Legionnaires’ disease, an aggressive and sometimes fatal form of pneumonia. In Sweden there are around ten outbreaks a year, most often with a preschool, a care home or a hospital as the point of spread. The property owner’s legal responsibility is unambiguous: temperatures must be checked, documented and corrected.

The temperature requirements, and why they are harder to meet than they sound

Boverket’s building regulations and the Public Health Agency of Sweden’s guidance on water temperature are clear: hot water at the tap must reach at least 50 °C, and in the circulation line at least 55 °C under all operating conditions. Cold water must be kept below 20 °C, which is especially important in the summer months when pipes run through heated spaces. What makes the requirements difficult in practice is that measured temperatures vary from one outlet to the next, and that variation is invisible from the central heating room.

ETI Legionella thermometer kit with three different probes

Why three different probes, not just one

ETI’s Legionella thermometer kit is built around a Therma® 1 base unit and complemented by three specialized probes. The combination is deliberate, because three different measurement situations call for three different measurement principles:

The immersion probe measures directly in the water stream through a tap. It is the fast method: open the tap fully, insert the probe, let the water run for at least three minutes so that any stagnant water is flushed out, then read the value. For outlets where you have running water, this is the gold standard.

The surface probe with precision strap measures the pipe from the outside. It is essential when you need to check the line in places where you can’t open a tap, for example in circulation system loops or in service shafts. The strap ensures good thermal contact between the probe and the pipe surface. The check takes longer (5–10 minutes to stabilize) but reveals the temperature profile along the entire system.

The PTFE wire probe is the flexible solution for tight spaces, such as behind a tiled wall or in places where a rigid immersion probe won’t fit. It is also suited to measuring in tanks where you need to get around an edge.

Where it’s used in practice

Property management: Under current regulations, property owners must have a self-monitoring plan for hot water. The kit makes that plan practical: the immersion probe for the annual main test, the surface probe for periodic temperature mapping, and the wire probe for difficult outlets such as shower heads behind wall panels.

Care homes and hospitals: Risk groups such as the elderly, the immunosuppressed and people with chronic lung disease are particularly susceptible to Legionella. Boverket and regional authorities often require more frequent checks in these properties. A complete kit on the building technician’s cart makes it possible to carry out checks during the daily round.

Hotels and conference facilities: Showers left unused during the low season are classic risk points. Before opening, every outlet must be flushed and checked, and the kit makes that round systematic.

Sports facilities and campsites: Cold showers in summer, where the hot water isn’t used regularly enough, create a risk environment. Regular temperature checks, and corrective action if the value doesn’t reach 50 °C, prevent problems before they arise.

What else the kit contains

In addition to the thermometer and the three probes, the kit includes: a countdown timer (necessary for correctly carrying out the three-minute flush), 100 probe wipes (for sanitizing between measurement points), an ABS carry case, and a free calibration certificate. The probes have Polygiene BioMaster product protection, an antimicrobial surface treatment that prevents cross-contamination between measurement points.

The price of SEK 2,550 is, for a normal property portfolio, a one-time cost that covers the equipment standard auditors expect. The alternative, a simple handheld thermometer without different probes, does not meet the requirements for systematic monitoring of a real water system.