Compact Dry XSA – for Staphylococcus Aureus – 500 test plates per pack, 38210000, Japan
7.444 SEK
- Clear and easy-to-use portable plate: No medium preparation is required, eliminating waste of medium as well as the need for sterilization equipment to prepare the medium.
- Detection of colonies on the plate is simple and clear.
- Individual colonies on the plate can be isolated for further identification tests
Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%
- Free shipping on orders over 3000 SEK excl. VAT
- Measuring instruments and hygiene tests for self-monitoring since 2003
- Call us +46 8 753 00 04
Description
Compact Dry X-SA is a simple and safe test method for detecting and quantifying Staphylococcus aureus. These are spherical bacteria that are typically arranged in clusters under the microscope. Their potential pathogenicity stems from their ability to produce enterotoxins (SET), which accumulate in food when contaminated and cannot be completely inactivated even by heat treatment. Food contamination with S. aureus almost always originates from humans (hands, sneezing, coughing). S. aureus is therefore also considered an indicator of inadequate personal hygiene
Incubation time and temperature: 24 ± 2 hours at 35 ± 2 °C, AOAC recommendation 35 ± 2 °C, NordVal /MicroVal recommendation 37 ± 1 °C
Shelf life: Room temperature (+ 1 to + 30 °C)
Storage: 21 months after manufacture
Sample preparation Viable count
in water or liquid food
Dispense 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.
Viable count in solid food
Add buffer solution to the sample and homogenize with a Stomacher®. Dispense 1 ml of sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.
Viable count in swab test samples
Use a cotton swab to wipe the surface, insert it into the unit with elution solution. Dispense 1 ml of elution solution (dilute if necessary) onto the center of the Compact Dry plate. It is recommended to use Swab for Compact Dry offered by HyServe Id no. 1 002 952/3 (40/240 pieces).
Test instructions
Open the lid and dispense 1 ml of sample onto the center of the Compact Dry plate.
The sample automatically and evenly diffuses into the pad, converting the dry pad into a gel within seconds.
Replace the lid on the plate and write the required information in the memo section.
Invert the covered plate and place it in the incubator.
After incubation, count the number of light blue/blue colonies. White paper placed under the plate helps in counting the colonies.