Compact Dry PA – for Pseudomonas Aeruginosa – 500 test plates per pack, 38210000, Japan
11.939 SEK
- Clear and easy-to-use portable plate: No medium preparation is required, eliminating waste of medium and the need for sterilization equipment to prepare the medium.
- Detection of colonies on the plate is simple and clear.
- Individual colonies on the plate can be isolated for further identification tests
Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%
- Free shipping on orders over 3000 SEK excl. VAT
- Measuring instruments and hygiene tests for self-monitoring since 2003
- Call us +46 8 753 00 04
Description
Compact Dry PA is a ready-to-use plate for the detection of Pseudomonas aeruginosa. Pseudomonas aeruginosa is a rod-shaped, Gram-negative, aerobic bacterium that can move through the medium via its unipolar flagellum. During incubation of the Compact Dry PA plate, growing colonies of P. aeruginosa develop a red color caused by the tetrazolium salt redox indicator present in the medium. It is distinguished from other pseudomonads by the formation of a greenish-yellow halo around the colony.
Scope of delivery
Incubation time and temperature: 45 – 51 hours at 34 – 36 °C
Shelf life: 12 months after manufacture
Storage: Room temperature (+ 1 to + 30 °C)
Sample preparation Viable count
Number in water or liquid food
Drop 1 ml of sample (dilute if necessary) in the center of the Compact Dry plate.
Viable count in water using membrane filtration
Add 1 ml of dilution fluid, e.g., peptone water or other suitable dilution fluid according to EN ISO 6887, in the center of the plate. Filter 100 ml of water sample (or more, e.g., 250 ml for bottled water) using a 47 mm diameter, sterile membrane with 0.45 µm pore size. Immediately after the end of filtration, apply the filter to the rehydrated Compact Dry plate. Ensure that the filtration side is facing up.
Viable count in solid food
Add a suitable volume of buffer solution (e.g., PBS, 1 part solid food + 9 parts buffer) to the sample and homogenize using a stomacher® and suitable stomacher® bags. Drop 1 ml of homogenized sample (dilute if necessary) in the center of the dry pad on the Compact Dry plate.
Viable count in swab test samples
Use the Compact Dry Swab offered by HyServe ID no. 1 002 952/3 (40/240 pieces) and wipe a suitable area of the surface, then return it to the unit with the elution solution. Shake the closed unit vigorously. Drop 1 ml of elution solution (dilute if necessary) in the center of the Compact Dry plate
Test instructions
1. Open the lid and drop 1 ml of sample in the center of the Compact Dry plate.
2. The sample automatically and evenly diffuses into the pad, converting the dry pad into a gel within seconds.
3. Replace the lid on the plate and write the required information in the memo section.
4. Invert the covered plate and place it in the incubator. 5. After incubation, count the number of colored colonies under the plate. Placing white paper under the plate helps in counting the colonies.

There are no reviews yet.