Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without Guessing

Compact Dry PA — the culture plate that makes in-house microbiological testing possible without an autoclave or media preparation

Published August 20, 2026 at 03:01

The temperature log is complete, all refrigerators are within limits, the cleaning schedule is signed off. Yet the self-inspection says nothing about the question that actually matters: is something growing in the facility? Temperature and cleaning routines are controlling factors — microbiological testing is the only thing that measures the result. And that is precisely the step that is most often skipped, because ”real microbiology” is associated with agar preparation, an autoclave, and a lab you don’t have.

Compact Dry PA ready-to-use culture plates for detection of Pseudomonas aeruginosa, 240 plates per package

What it is

Compact Dry PA is a ready-to-use culture plate for detection of Pseudomonas aeruginosa, supplied in a package of 240 plates. The medium sits dry in the plate and is activated by the sample’s own liquid — you simply drop 1 ml of sample in the center, and the liquid spreads evenly across the surface by itself. Incubation takes 45–51 hours at 34–36 °C. The plates are stored at room temperature (+1 to +30 °C) and have a shelf life of 12 months from the date of manufacture.

The problem it solves

The classic barrier to microbiological self-inspection isn’t the analysis — it’s the preparation. Boiling and pouring medium requires equipment, an autoclave for sterilization, and planning, since leftover medium is discarded. Compact Dry removes that entire step: the plate is ready to use, keeps for a year, and is stored at room temperature — on a shelf rather than in a refrigerator that’s already full anyway. You use one plate when you need one plate — not an entire batch because you had to prepare medium.

The reading is the other half. The medium contains tetrazolium salt as a redox indicator, which causes growing colonies of P. aeruginosa to turn red. In addition, this particular species forms a yellow-green halo around the colony — a second, independent trait that distinguishes it from other pseudomonads. So there’s no need to interpret faint dots against backlight: the result is clearly readable, and individual colonies can be picked from the plate for further identification if something needs to be followed up.

The method is also flexible in terms of sample type. A water sample or liquid food is dosed directly with 1 ml. For a lower detection level — for example with bottled water — you filter 100 ml or more through a 0.45 µm membrane filter and place the filter on a rehydrated plate. Solid foods are first homogenized in buffer, typically at a ratio of one part sample to nine parts buffer.

Three typical use cases

  • Water and beverages: control of process water, bottled water, and taps, where P. aeruginosa is an established indicator organism and membrane filtration provides the sensitivity required.
  • Food production with wet environments: floor drains, hoses, rinse tables, and cooling water systems — the places where biofilm forms and where cleaning results need to be verified, not just ticked off.
  • Post-cleaning verification: sampling before and after a resolved issue, so you can demonstrate that the measure actually worked — not just that it was carried out.

Why it pays off

First, consider the alternative of sending samples externally: shipping costs, a lead time of several days, and an analysis fee per sample that means few samples get taken. With plates on the shelf, the marginal cost per sample becomes so low that testing can become routine rather than the exception — and it’s the number of samples, not the refinement of the method, that determines whether a problem is caught while it’s still small.

Then there’s the cost no one budgets for: a recalled batch, a shut-down production line, or a customer switching supplier. In every case, the decisive question is whether the company can show when the problem arose and what the testing showed beforehand. A series of documented test results is what makes the difference between a contained incident and total uncertainty about how far back the deviation goes.

Read more about Compact Dry PA culture plates, 240 pcs →