Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Air temperature in the fridge doesn’t tell you how warm the product isThe fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Air temperature in the fridge doesn’t tell you how warm the product isThe fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspections

Kikkoman Allergen Lateral Flow EASY Kit for PEANUT: When a 10-minute immunoassay on the factory line confirms the cleaning SOP actually removed the peanut Ara h 1 protein before the next allergen-free batch starts

Published 16 July 2026 at 03:03

Peanut allergy is the MOST DEADLY food allergy worldwide. Clinical data:

  • Prevalence: ~2-4% of adults, ~3-6% of children in the Western world.
  • Anaphylaxis threshold: 0.25-0.4 mg of peanut protein (extremely low, equivalent to <1/10 of a single peanut).
  • Anaphylaxis mortality: ~1-2% without prompt epinephrine.
  • On average, ~5-10 deaths per year in Sweden are caused by failed allergen management.

The food industry handles peanut allergen with three different strategies:

  1. Completely peanut-free factory: No peanut ingredients EVER on the premises. The simplest to manage, but it limits the product portfolio.
  2. Segregated production line: Separate lines for peanut and peanut-free products. Costly but safe.
  3. Shared line with cleaning between batches: The same line is used for both; rigorous cleaning between shifts. Economically efficient but REQUIRES VERIFICATION that the cleaning is complete.

The Kikkoman Allergen Lateral Flow EASY Kit is the verification tool for strategy 3.

Ara h 1 — the major peanut allergen

Peanut allergen consists of several different proteins. The most clinically relevant are:

  • Ara h 1: Vicilin family (7S seed storage protein). The DOMINANT sensitizing agent. ~95% of peanut-allergic patients have antibodies against Ara h 1.
  • Ara h 2: Conglutin family (2S albumin). Also a potent allergen, associated with SEVERE reactions.
  • Ara h 3: Glycinin family (11S legumin).
  • Ara h 6-9: Secondary allergens.

The EASY Kit test specifically detects Ara h 1 with high sensitivity. This is the appropriate MARKER for peanut contamination — if Ara h 1 is absent, it can be stated with a high degree of certainty that peanut material is absent.

Lateral flow immunoassay technology

Lateral flow is an immunochromatographic technique (the same basic technology as COVID-19 antigen tests and pregnancy tests):

  1. Test strip construction: A strip of nitrocellulose paper with pretreated zones: sample application zone, conjugate zone, test line, control line.
  2. Conjugate zone: Contains ”gold nanoparticles conjugated with anti-Ara h 1 antibodies”. The gold provides a visible red color.
  3. Test line: Immobilized anti-Ara h 1 antibodies (a different epitope than the conjugate).
  4. Control line: Immobilized anti-mouse IgG (captures all conjugate that passes through, verifying that the test has worked).

If Ara h 1 is present in the sample: The sample flows from the application zone → the conjugate binds to Ara h 1 → the gold-Ara h 1 complex flows onward → binds to the antibodies on the test line → VISIBLE RED LINE on the test line. Positive result.

If Ara h 1 is absent: No conjugate-Ara h 1 binding → the gold flows straight through the test line → binds only to the control line. Only ONE red line (control). Negative result.

Test fails (invalid): No line appears at all, or only the test line without the control line. The test is defective or expired.

Detection limit and specificity

EASY Kit peanut specifications:

  • Detection limit: ~1 ppm peanut protein (1 μg per gram of sample).
  • Specificity: No cross-reactivity with other common nuts (almond, cashew, hazelnut). No cross-reactivity with soy or other legumes.
  • False-positive rate: <1% in standard tests.
  • False-negative rate: <5% at ppm concentrations above the detection limit.

Practical consequence: a negative test confirms with ~99%+ certainty that peanut protein is BELOW 1 ppm — more than 400 times below the anaphylaxis threshold (0.4 mg = 400 ppm in a 1 g dose).

Workflow: swab or rinse water

The test can be used on TWO different sample types:

SWAB test (for dry surfaces):

  1. Open the swab pouch (ST-25 included in the kit).
  2. Squeeze the swab to remove excess moisture.
  3. Wipe the suspect surface (typically 10×10 cm) thoroughly with the swab.
  4. Place the swab in the included buffer bottle.
  5. Shake vigorously for 10-15 seconds to extract protein from the swab.
  6. Apply 4 drops of the solution to the test strip.
  7. Wait 10 minutes.
  8. Read the result: 1 line = negative, 2 lines = positive.

Rinse water test (for CIP verification):

  1. After CIP (Clean-in-Place) cleaning of the production line, collect rinse water from the final outlet.
  2. Shake the rinse water sample.
  3. Apply 4 drops directly to the test strip.
  4. Wait 10 minutes.
  5. Read the result.

The rinse water test is the PROFESSIONAL method for the food industry — it collects peanut residues from the ENTIRE internal passage of the line, not just a single surface.

What a NEGATIVE test does NOT prove

An important NUANCE: a negative test proves that the TESTED LOCATION has <1 ppm peanut protein. It does NOT prove that the ENTIRE facility is peanut-free.

Standard practice requires multiple test points for serious verification:

  • Rinse water from 3-5 different pipes/outlets.
  • Swabs of mixer blades, conveyor belts, packing heads.
  • Swabs of work surfaces, shelves, tools.
  • A total of 10-20 test points per verification round.

Regulatory requirements and EU legislation

EU Regulation 1169/2011 requires that all 14 major allergens (including peanut) be DECLARED on the packaging if they are present AS INGREDIENTS.

”Contains” vs ”May contain”:

  • ”Contains peanut” = intentional ingredient. Standard declaration.
  • ”May contain peanut” = risk of unintentional cross-contamination. Not formally regulated, but declared VOLUNTARILY to protect consumers and companies.

The VITAL 3.0 standard (Voluntary Incidental Trace Allergen Labelling): An Australian/New Zealand industry consensus that specifies threshold values for when a ”may contain” declaration is REQUIRED:

  • Peanut: 0.2 mg per portion (200 mg/kg = 200 ppm in a 1 g portion).

The EASY Kit’s 1 ppm detection is FAR below the VITAL 3.0 threshold — a negative test confirms with a comfortable margin that the product does not need a ”may contain” warning.

Applications

Chocolate manufacturing: The classic application. Chocolate factories often produce BOTH peanut chocolate AND peanut-free chocolate on the same lines. CIP verification is critical.

Bakery and cake manufacturing: Multi-product production with varying allergen profiles.

Biscuit and snack manufacturing: Mixed-nut products often share lines with non-nut products.

Ice cream and dessert production: Ice cream with peanut mix-ins shares production equipment with plain vanilla products.

Ready meal production: Multiple menu options require strict allergen management.

Restaurant service: Verification of table, dishwashing and kitchen surfaces after peanut-containing dishes.

School meals: Verification that the school kitchen is peanut-free when a ”peanut-free school” policy applies.

Hospital and care home catering: Critical for patients with known allergies.

Airline catering: Verification of special allergy-friendly meals.

Economic rationale: the cost of an allergen recall

An allergen recall from the market is EXTREMELY EXPENSIVE:

  • Average cost of a product recall in the EU: EUR 10-50 million (product returns, inventory costs, transport, PR crisis management).
  • Fatal cases: potential civil liability of EUR 50-500 million.
  • Brand damage: long-term sales decline of 20-40% over 2-5 years.

The cost of a peanut test: ~SEK 200 per test (EASY Kit 10-pack for SEK 1,768).

Verification workflow with 10 test points per shift × 300 shifts per year = 3000 tests × SEK 200 = SEK 600,000 per year.

This is LESS THAN 1% of the cost of a single recall. Systematic allergen testing is the most cost-effective risk management in the food industry.

Alternatives to the lateral flow test

ELISA test (Kikkoman Allergen ELISA II for peanut): ~SEK 7,000-8,000 per 96-test kit. Quantitative (gives a ppm value). Better precision but requires a plate reader (~SEK 30,000) + 3-4 hours of work per test round.

PCR-based test: Detects peanut DNA instead of protein. Much more sensitive (0.1 ppm) but requires PCR laboratory equipment + 4-8 hours of analysis.

Mass spectrometry-based: The absolute-precision method. Requires a full laboratory. 4-8 hours per sample.

This EASY Kit (Lateral Flow): QUALITATIVE (yes/no), fast (10 min), simple (no lab equipment), inexpensive (~SEK 200/test). Perfect for PRODUCTION LINE VERIFICATION where a yes/no answer is sufficient.

Practical decision logic

  • Screening (daily / per batch): Use the EASY Kit — fast, simple, inexpensive.
  • Trend analysis (monthly): Use ELISA for quantification.
  • Investigation during a recall / complex event: Use PCR or mass spectrometry for definitive analysis.

Storage and handling

  • Store at 2-8 °C (refrigerator).
  • MUST NOT BE FROZEN — freezing permanently destroys the antibody conjugate.
  • Use before the expiry date (typically 12-18 months from manufacture).
  • After opening the bottle: use within the recommended time (typically 24-48 hours).

Specifications

  • Model: Kikkoman Allergen Lateral Flow Rapid Test EASY Kit — Peanut.
  • Target protein: Ara h 1 (major peanut allergen).
  • Number of tests: 10 per kit.
  • Application methods: swab (ST-25 included) AND rinse water.
  • Analysis time: 10 minutes.
  • No sample preparation required.
  • Detection limit: ~1 ppm peanut protein.
  • Specificity: high (no cross-reactivity with other nuts).
  • Storage: 2-8 °C. DO NOT FREEZE.
  • Reading method: visual (red line on the test strip).
  • Compatible variants are available for other allergens (milk, egg, gluten, sesame, crustaceans).

What you get for your money

Kikkoman Allergen Lateral Flow Rapid Test EASY Kit for peanut, 10 tests per pack, compatible with both swab samples (ST-25 swab set included) and rinse water samples, 10-minute analysis time without sample preparation, detection limit ~1 ppm peanut protein, high specificity (no cross-reactivity with other nuts), storage at 2-8 °C. SEK 1,768 per 10-pack = ~SEK 177 per test.

The standard tool for chocolate manufacturing, bakeries, the biscuit and snack industry, ice cream production, ready meal production, restaurant service, school meals, hospital catering, airline catering and other applications where verification of peanut cross-contamination is required between production batches. The added cost over ”no testing” is overwhelmingly justified: a single failed batch with peanut contamination can cost EUR 10-500 million in recall and civil liability — SEK 177 per verification test is economically trivial.

Read more: Kikkoman Peanut Lateral Flow Kit in the store →

More news

All news