Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batchVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batch
Item number 76-1502879-040

Compact Dry TC – for total bacterial count – 40 test plates per pack, 38210000, Japan

792 SEK

In stock
  • Clear and easy-to-use portable plate: No medium preparation is required, eliminating waste of medium as well as the need for sterilization equipment to prepare the medium.
  • Detection of colonies on the plate is simple and clear.
  • Individual colonies on the plate can be isolated for further identification tests
Request a quote 76-1502879-040

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and hygiene tests for self-monitoring since 2003
  • Call us +46 8 753 00 04

Category:

Description

Compact Dry TC is a medium for total viable bacterial count, containing nutrient agar. The colonies grown on Compact Dry TC are red due to the redox indicator tetrazolium salt.
Regression line data from the Compact Dry TC method plotted against the conventional PCA method (standard plate count agar) shows a good correlation per 100 food samples for the population of mesophilic aerobic microorganisms. Compact Dry TC is AOAC-, MicroVal- and NordVal-approved.


Incubation time and temperature: 48 ± 3 hours at the temperature recommended by AOAC 35 ± 2 °C, NordVal / MicroVal 30 ± 2 °C
Shelf life: 24 months after manufacture
Storage: Room temperature (+ 1 to + 30 °C)


Sample preparation Viable count
in water or liquid food
Dispense 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.
Viable count in solid food
Add buffer solution to the sample and homogenize with a Stomacher®. Dispense 1 ml of sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.
Viable count in swab test samples
Use the cotton swab to wipe the surface, insert it into the device with the elution solution. Dispense 1 ml of elution solution (dilute if necessary) onto the center of the Compact Dry plate. It is recommended to use ”Swab for Compact Dry” offered by HyServe Id no. 1 002 952/3 (40/240 pieces).
Test instructions
1. Open the lid and dispense 1 ml of sample onto the center of the Compact Dry plate.
2. The sample automatically and evenly diffuses into the pad, converting the dried pad into a gel within seconds.
3. Replace the lid on the plate and write the necessary information in the memo section.
4. Turn the covered plate upside down and place it in the incubator.
5. After incubation, count the number of colored colonies under the plate. White paper placed under the plate helps to count the colonies

Specification

Compact Dry TC is a medium for total viable bacterial count, containing nutrient agar. The colonies grown on Compact Dry TC are red due to the redox indicator tetrazolium salt.
Regression line data from the Compact Dry TC method plotted against the conventional PCA method (standard plate count agar) shows a good correlation per 100 food samples for the population of mesophilic aerobic microorganisms. Compact Dry TC is AOAC-, MicroVal- and NordVal-approved.


Incubation time and temperature: 48 ± 3 hours at the temperature recommended by AOAC 35 ± 2 °C, NordVal / MicroVal 30 ± 2 °C
Shelf life: 24 months after manufacture
Storage: Room temperature (+ 1 to + 30 °C)


Sample preparation Viable count
in water or liquid food
Dispense 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.
Viable count in solid food
Add buffer solution to the sample and homogenize with a Stomacher®. Dispense 1 ml of sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.
Viable count in swab test samples
Use the cotton swab to wipe the surface, insert it into the device with the elution solution. Dispense 1 ml of elution solution (dilute if necessary) onto the center of the Compact Dry plate. It is recommended to use ”Swab for Compact Dry” offered by HyServe Id no. 1 002 952/3 (40/240 pieces).
Test instructions
1. Open the lid and dispense 1 ml of sample onto the center of the Compact Dry plate.
2. The sample automatically and evenly diffuses into the pad, converting the dried pad into a gel within seconds.
3. Replace the lid on the plate and write the necessary information in the memo section.
4. Turn the covered plate upside down and place it in the incubator.
5. After incubation, count the number of colored colonies under the plate. White paper placed under the plate helps to count the colonies