Hoppa till innehåll
Free shipping over 5.552 SEK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batchVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batch
Item number 76-1502880-240

Compact Dry EC – for E. coli & coliform bacteria – 240 test plates per pack, 38210000, Japan

3.690 SEK

In stock
  • Clear and easy-to-use portable plate: No medium preparation is required, eliminating waste of medium and the need for sterilization equipment to prepare the medium.
  • Detection of colonies on the plate is simple and clear.
  • Individual colonies on the plate can be isolated for further identification tests.
Request a quote 76-1502880-240

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and hygiene tests for self-monitoring since 2003
  • Call us +46 8 753 00 04

Category:

Description

Compact Dry EC is a medium for E. coli and coliform bacteria. Coliform bacteria are considered indicator bacteria for fecal contamination. E. coli is the most well-known representative of the coliform group and is considered an indicator for the presence of other pathogenic organisms. The medium contains two types of chromogenic enzyme substrates: Magenta-Gal and X-Gluc. E. coli forms blue colonies. The total number of coliform groups is the sum of both the red and blue colonies.
Scope of delivery


Incubation time: 24 hours

Incubation temperature: 24 ± 2 hours , at temperature recommendation of MicroVal/ NordVal 37 ± 1 °C AOAC 35 ± 2 °C

Shelf life: 24 months after manufacture


Viability count in water or liquid food

Drop 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.

Viability count in solid food

Add buffer solution to the sample and homogenize with stomacher®. Drop 1 ml of sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.  

Viability count in swab test samples

Use a sterile wet wipe to wipe the surface to be analyzed and place it back into the device with the rinse solution.  

Drop 1 ml of rinse solution (dilute if necessary) onto the center of the Compact Dry plate.  

Use Compact Dry Swab (art. No. ZCS1002953, content 40 pcs) as a single application (1 ml) or Promedia ST-25 (art. No. Z0302, content 10 pcs) as a multiple application (10 ml) for this procedure.

Specification

Compact Dry EC is a medium for E. coli and coliform bacteria. Coliform bacteria are considered indicator bacteria for fecal contamination. E. coli is the most well-known representative of the coliform group and is considered an indicator for the presence of other pathogenic organisms. The medium contains two types of chromogenic enzyme substrates: Magenta-Gal and X-Gluc. E. coli forms blue colonies. The total number of coliform groups is the sum of both the red and blue colonies.
Scope of delivery


Incubation time: 24 hours

Incubation temperature: 24 ± 2 hours , at temperature recommendation of MicroVal/ NordVal 37 ± 1 °C AOAC 35 ± 2 °C

Shelf life: 24 months after manufacture


Viability count in water or liquid food

Drop 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.

Viability count in solid food

Add buffer solution to the sample and homogenize with stomacher®. Drop 1 ml of sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.  

Viability count in swab test samples

Use a sterile wet wipe to wipe the surface to be analyzed and place it back into the device with the rinse solution.  

Drop 1 ml of rinse solution (dilute if necessary) onto the center of the Compact Dry plate.  

Use Compact Dry Swab (art. No. ZCS1002953, content 40 pcs) as a single application (1 ml) or Promedia ST-25 (art. No. Z0302, content 10 pcs) as a multiple application (10 ml) for this procedure.

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *