Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without Guessing
Item number 56-TR-74UI

TandD Logger for light level (lux), UV, temperature and humidity, 4 channels, USB. With external lux/UV sensor ISA-3151

3.737 SEK

In stock

TandD Logger for light level (lux), UV, temperature and humidity, 4 channels, USB. With external lux/UV sensor ISA-3151

Request a quote 56-TR-74UI

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and hygiene tests for self-monitoring since 2003
  • Call us +46 8 753 00 04

Category: , , , , ,

Other models in the series 6

Description

The 56-TR-74UI is TandD’s 4-in-1 light and climate logger — simultaneously measures illuminance (lux), UV intensity, temperature, and humidity via two included external sensors: the light/UV sensor ISA-3151 and the T/RH sensor THA-3151. Connect directly to a PC via USB for configuration and data download.

The measurement range spans from moonlight (0.01 lx resolution) to direct summer sun (130 klx), making the logger suitable for environments ranging from museums and archives with strict light limitations to full-sun cultivation. Built-in display of cumulative light exposure (0–90 Mlxh) and cumulative UV exposure (0–62 W/cm²·h) directly on the LCD — perfect for documenting total light load on sensitive objects over time.

Features

  • 4 channels: illuminance, UV intensity, temperature, and humidity
  • Light range: 0.01 lx to 130 klx — moonlight to direct sunlight
  • UV range: 0 to 30 mW/cm² (260–400 nm UVA/UVB)
  • T/RH with included THA-3151: 0–55 °C / 10–95 %RH
  • Cumulative light exposure: 0 to 90 Mlxh
  • Cumulative UV exposure: 0 to 62 W/cm²·h
  • Direct USB 2.0 Mini-B connection to PC
  • 8,000 data point memory
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • Powered by 1 × AA battery for approx. 6 months
  • Front-panel buttons for manual operation
  • Built-in LCD with rotation of all values + cumulative displays

Specification

Measurement channels Light + UV + Temperature + Humidity — 1 channel each
Light measurement range 0 lx to 130 klx (resolution 0.01 lx)
UV measurement range 0 to 30 mW/cm² (260–400 nm)
T/RH measurement range 0 to +55 °C / 10 to 95 %RH
Light/UV accuracy ±5 % at 25 °C, 50 %RH
T/RH accuracy ±0.5 °C / ±5 %RH (at 25 °C, 50 %RH)
Response time (90 %) T/RH: approx. 7 min; Light/UV: 3 sec (1 sec interval) / 6 sec (other)
Logging capacity 8,000 data points
Cumulative light 0 to 90 Mlxh
Cumulative UV 0 to 62 W/cm²·h
Communication USB 2.0 Mini-B, serial (via optional cable 56-TR-07C)
Power supply 1 × AA alkaline LR6
Battery life approx. 6 months
Dimensions 55 × 78 × 18 mm
Weight approx. 40 g

Included

  • 56-TR-74UI logger
  • 1 × AA alkaline battery
  • Light/UV sensor 56-ISA-3151
  • T/RH sensor 56-THA-3151
  • USB Mini-B cable 56-US-15C
  • Manual set with warranty certificate

Applications

The 56-TR-74UI is chosen for conservation environments and outdoor applications: museums (painting galleries, photo collections, textile archives), galleries, libraries, heritage buildings, greenhouses and solar panel installations, photo studios, light therapy rooms, and clinical phototesting. For high precision (±2.5 %RH), see 56-TR-74UI-S. For CO₂ instead of light, see 56-TR-76UI.