Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without Guessing
Item number 56-RTR502BL

TandD Wireless Temperature Logger with External Probe, Large Battery Compartment (Batteries Not Included). Measuring Range -60 to +155 °C Depending on Probe. Bluetooth

2.107 SEK

In stock

TandD Wireless temperature logger with external sensor, large battery compartment (batteries not included). Measuring range -60 to +155 °C depending on sensor. Bluetooth

Request a quote 56-RTR502BL

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and hygiene tests for self-monitoring since 2003
  • Call us +46 8 753 00 04

Category: , , ,

Other models in the series 16

Description

The 56-RTR502BL is the L-model of the 56-RTR502B temperature logger — same electronics, same -60 to +155 °C measuring range via external probe on cable, but with a large battery compartment for LS26500 C-cell lithium batteries providing approx. 4 years of operation between battery changes. Four times longer than the standard model.

Designed for long-term installations where battery replacement is costly or inconvenient — fixed processes, remote sites, warehouse monitoring installations. The probe (TR-5106 standard, or alternative probes for specific applications) is inserted into the measuring point while the logger unit is placed in a secure location with wireless transmission to the base unit.

Features

  • External thermistor probe on cable — flexible placement
  • Measuring range -60 to +155 °C (depending on selected probe)
  • Fast response time (varies with probe)
  • IP64 splash protection on the logger unit itself
  • Battery life approx. 4 years with LS26500 (sold separately)
  • Wireless range approx. 150 meters line of sight
  • 16,000 data point memory (Endless mode)
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • Built-in LCD displays current temperature and battery warning
  • Bluetooth 4.2 BLE for configuration via mobile app

Specification

Measuring channel Temperature 1 channel — thermistor (external, on cable)
Measuring range -60 to +155 °C (depending on probe)
Accuracy ±0.3 °C (-20 to 80 °C), ±0.5 °C (-40 to -20 °C, 80 to 110 °C), ±1.0 °C (-60 to -40 °C, 110 to 155 °C)
Resolution 0.1 °C
Logging capacity 16,000 data points
Wireless communication EU: 869.7–870 MHz, RF power 5 mW, range approx. 150 m
Other interfaces Bluetooth 4.2 BLE, optical communication
Protection class IP64 (daily splash protection)
Power supply Large battery compartment for LS26500 C-cell lithium (not included)
Battery life approx. 4 years
Dimensions 62 × 47 × 46.5 mm (excl. protruding parts and probe)
Weight approx. 65 g
Operating environment -40 to +80 °C (during wireless transmission: -30 to +80 °C)
Compatible base units 56-RTR500BC, 56-RTR500BW, 56-RTR500BM

Included

  • 56-RTR502BL logger with large battery compartment
  • External thermistor probe 56-TR-5106
  • Manual set with warranty certificate

Sold separately (required for operation)

  • LS26500 C-cell lithium battery — contact your distributor
  • 56-RTR-500B1 as a complete battery pack kit

Applications

The 56-RTR502BL is suitable for fixed process monitoring where the logger is installed and left unattended for several years: industrial temperature monitoring (ovens, heat treatment, autoclaves), pharmaceutical storage with long shelf lives, freezer monitoring, water-based heating systems, and remote sites without PC access. For the standard model with shorter battery life but included battery supply, see 56-RTR502B.

Additional information
Product Type

Measures

Lämpötila

Communication

Langaton Bluetooth, Langaton pitkä kantama