ETI TDS2 ppm conductivity meter. Measures ppm (parts per million). Resolution 100ppm, range 100-9999
1.224 SEK
TDS Conductivity Tester
- Genuinely pocket-sized
- Easy-to-read 6 mm LCD display
- Indicates ppm (parts per million) or µS (micro-siemens)
- Accuracy of ±2% of full scale
Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%
- Free shipping on orders over 3000 SEK excl. VAT
- Measuring instruments and hygiene tests for self-monitoring since 2003
- Call us +46 8 753 00 04
Description
These TDS conductivity meters provide the perfect solution for measuring ppm or μS. The TDS meters are ideal for monitoring a wide range of applications, including the amount of salts or dissolved solids in water. Readings are automatically temperature compensated within the range of 0 to 50 °C.
There are two models of both TDS and conductivity meters, suitable for either low or high concentrations of total dissolved solids in liquids.
Conductivity Electrode Maintenance
The ETI range of conductivity meters includes TDS meters, nutrient meters, salt concentration meters, and WalkLAB Pro conductivity meters.
Various calibration solutions are available for regular calibration of the instruments.
Storage: It is best to store cells with the electrodes immersed in deionized water. All cells that have been stored dry should be soaked in distilled water for 5 to 10 minutes before use to ensure complete wetting of the electrodes.
The single most important requirement for accurate and reproducible results in conductivity measurement is a clean cell. A dirty cell will contaminate the solution and cause the conductivity to change. Grease, oil, fingerprints, and other contaminants on the sensing elements can cause inaccurate measurements and sporadic reactions.
Electrodes can be cleaned with a mixture of 1 volume part isopropyl alcohol, 1 part ethyl ether, and 1 part HCl (1+1). After cleaning, rinse the cell thoroughly with water. If the old platinum black coating needs to be removed, it is often successful to apply aqua regia to the electrodes, or perform electrolysis in HCl. This should only be attempted by trained operators.
Electrodes can also be cleaned with detergents and/or nitric acid (1%) by dipping or filling the cell with the cleaning solution and stirring for two or three minutes.
Rinse the cell several times with distilled or deionized water and measure the cell constant before use.
| Range: | TDS1: 10-1990, TDS2: 100-9999, COND3: 10-1990, COND4: 100-19900 |
|---|---|
| Resolution: | TDS1: 10 ppm, TDS2: 100 ppm, COND3: 10µS, COND4: 100µS |
| Accuracy: | ±2% of full scale |
| Battery: | 4 x 1.5 volt LR44 button cell |
| Battery life: | 100 hours |
| Display: | 6 mm LCD |
| Dimensions: | 15 x 32 x 147 mm |
| Weight: | 70 grams |
| Packaging material: | ABS plastic |
| Warranty: | one year |
| Water/dust resistance: | waterproof |
| Measurement scale: | ppm (TDS1 & TDS2) or µS (COND3 & COND4) |