Hoppa till innehåll
Free shipping over 5.552 SEK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batchVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batch
Item number 53-SDL150

Meters/SD loggers for dissolved oxygen

9.503 SEK

In stock

Records data to an SD card in Excel® format

Documents:sdl150data
Request a quote 53-SDL150

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and hygiene tests for self-monitoring since 2003
  • Call us +46 8 753 00 04

Category:

Description
  • Dual background-lit display for oxygen concentration and temperature
  • Measures free oxygen from 0 to 20.0 mg / L and 0 to 100.0% oxygen, including temperature from 0 to 50 °C
  • Automatic temperature compensation from 0 to 50 °C via temperature sensor built into the polarographic oxygen probe
  • Offset adjustment is used for zero adjustment to perform relative measurements
  • Saves 99 readings manually and 20 million data values via 2G SD card
  • Programmable sampling frequency
  • Built-in PC interface for PC connection
  • Min / Max and Data-Hold function, automatic shutdown
  • Complete with 6 x AA batteries, SD card, probe, two extra replacement membranes, electrolyte and hard case
Specification
  • Dual background-lit display for oxygen concentration and temperature
  • Measures free oxygen from 0 to 20.0 mg / L and 0 to 100.0% oxygen, including temperature from 0 to 50 °C
  • Automatic temperature compensation from 0 to 50 °C via temperature sensor built into the polarographic oxygen probe
  • Offset adjustment is used for zero adjustment to perform relative measurements
  • Saves 99 readings manually and 20 million data values via 2G SD card
  • Programmable sampling frequency
  • Built-in PC interface for PC connection
  • Min / Max and Data-Hold function, automatic shutdown
  • Complete with 6 x AA batteries, SD card, probe, two extra replacement membranes, electrolyte and hard case
PDF (1)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *