Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batchVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Legionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingHow to know your thermometer reads correctly before a faulty reading costs you an entire batch
Item number 78-1061342

Histamine test strips, 40 pcs / pack, 38221900, Japan

3.307 SEK

In stock
  • Color change indicating histamine content
  • Simple & easy test
  • No instrumentation required
  • Fast results
  • No special training required
Request a quote 78-1061342

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and hygiene tests for self-monitoring since 2003
  • Call us +46 8 753 00 04

Category:

Description

78-1061342 Test allergens > Test strips for histamine

The Histamine Control Strip should be used to analyze histamine present in food samples using a colorimetric reaction. Analysis results can be verified by changes in reagent color. Comparing color changes with the color chart provides a rough understanding of the histamine content.
The analysis method for this product contains enzymes that act specifically on histamine. In the presence of tetrazolium salt and electron acceptors, histamine dehydrogenase acts on the tetrazolium salt to produce formazan dye (purple). Since the concentration of formazan dye varies depending on the histamine concentration, a rough understanding of the histamine concentration in the sample can be obtained by comparing it with the color chart.
This product simplifies the process of identifying histamine concentration in analysis samples, but it is not intended for exact quantification of histamine or as an official analysis method.

1 x box, 40 analyses (20 x 2 aluminum bags)


Measurement time: 5 min

Storage: 2-8 ℃ (Do not freeze)

Quantitative range: 20–80 ppm (for fish sauce: 5-fold diluted fish sauce becomes 100-400 ppm)

Detection method: Visual reading of colorimetric reaction


Remove the product from the refrigerator and allow it to reach room temperature (18 – 30℃). Once the product has reached room temperature, it should be used as soon as possible.

Dilute an analysis sample two to five times. Solid analysis samples should be ground. False positive results can be prevented by heating the diluted sample. 

Pull the strip out of the main body.

Immerse the strip in the diluted sample. If the analysis sample is in solid form, ensure no solid particles stick to the strip. 

Return the strip to the main body and push it fully into the main body.

Hold the main body and shake it. The remaining colorimetric reagent will dissolve completely. 

After five minutes, check the color of the reaction solution. A rough understanding of the histamine concentration can be obtained by comparing the color with the color chart.