Hoppa till innehåll
Free shipping over 5.569 SEK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without Guessing
Item number 76-1502949-240

Compact Dry PA – for Pseudomonas Aeruginosa – 240 test plates per pack, 38210000, Japan

6.110 SEK

In stock
  • Clear and easy-to-use portable plate: No medium preparation is required, eliminating waste of medium and the need for sterilization equipment to prepare the medium.
  • Detection of colonies on the plate is simple and clear.
  • Individual colonies on the plate can be isolated for further identification tests.
Request a quote 76-1502949-240

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 SEK excl. VAT
  • Measuring instruments and hygiene tests for self-monitoring since 2003
  • Call us +46 8 753 00 04

Category:

Description

Compact Dry PA is a ready-to-use plate for the detection of Pseudomonas aeruginosa. Pseudomonas aeruginosa is a rod-shaped, Gram-negative, aerobic bacterium that can move through the medium via its unipolar flagellum. During incubation of the Compact Dry PA plate, growing colonies of P. aeruginosa develop a red color caused by the tetrazolium salt redox indicator present in the medium. It is distinguished from other pseudomonads by the formation of a greenish-yellow halo around the colony.
Scope of delivery


Incubation time and temperature: 45 – 51 hours at 34 – 36 °C
Shelf life: 12 months after manufacture
Storage: Room temperature (+ 1 to + 30 °C)


Sample preparation Viable count

Number in water or liquid food
Drop 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.

Viable count in water using membrane filtration
Add 1 ml of dilution fluid, e.g., peptone water or another suitable dilution fluid according to EN ISO 6887, to the center of the plate. Filter 100 ml of water sample (or more, e.g., 250 ml for bottled water) using a sterile membrane with a 47 mm diameter and 0.45 µm pore size. Immediately after the end of filtration, place the filter on the rehydrated Compact Dry plate. Ensure that the filtration side is facing up.

Viable count in solid food
Add an appropriate volume of buffer solution (e.g., PBS, 1 part solid food + 9 parts buffer) to the sample and homogenize using a Stomacher® and appropriate Stomacher® bags. Drop 1 ml of the homogenized sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.

Viable count in swab test samples
Use the Compact Dry Swab offered by HyServe ID no. 1 002 952/3 (40/240 pieces) and wipe an appropriate area of the surface, then return it to the unit with the elution solution. Shake the closed unit vigorously. Drop 1 ml of elution solution (dilute if necessary) onto the center of the Compact Dry plate.

Test instructions
1. Open the lid and drop 1 ml of sample onto the center of the Compact Dry plate.
2. The sample automatically and evenly diffuses into the pad, converting the dry pad into a gel within a few seconds.
3. Replace the lid on the plate and write the required information in the memo section.
4. Invert the covered plate and place it in the incubator. 5. After incubation, count the number of colored colonies under the plate. Placing white paper under the plate helps in counting the colonies.

Specification

Compact Dry PA is a ready-to-use plate for the detection of Pseudomonas aeruginosa. Pseudomonas aeruginosa is a rod-shaped, Gram-negative, aerobic bacterium that can move through the medium via its unipolar flagellum. During incubation of the Compact Dry PA plate, growing colonies of P. aeruginosa develop a red color caused by the tetrazolium salt redox indicator present in the medium. It is distinguished from other pseudomonads by the formation of a greenish-yellow halo around the colony.
Scope of delivery


Incubation time and temperature: 45 – 51 hours at 34 – 36 °C
Shelf life: 12 months after manufacture
Storage: Room temperature (+ 1 to + 30 °C)


Sample preparation Viable count

Number in water or liquid food
Drop 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.

Viable count in water using membrane filtration
Add 1 ml of dilution fluid, e.g., peptone water or another suitable dilution fluid according to EN ISO 6887, to the center of the plate. Filter 100 ml of water sample (or more, e.g., 250 ml for bottled water) using a sterile membrane with a 47 mm diameter and 0.45 µm pore size. Immediately after the end of filtration, place the filter on the rehydrated Compact Dry plate. Ensure that the filtration side is facing up.

Viable count in solid food
Add an appropriate volume of buffer solution (e.g., PBS, 1 part solid food + 9 parts buffer) to the sample and homogenize using a Stomacher® and appropriate Stomacher® bags. Drop 1 ml of the homogenized sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.

Viable count in swab test samples
Use the Compact Dry Swab offered by HyServe ID no. 1 002 952/3 (40/240 pieces) and wipe an appropriate area of the surface, then return it to the unit with the elution solution. Shake the closed unit vigorously. Drop 1 ml of elution solution (dilute if necessary) onto the center of the Compact Dry plate.

Test instructions
1. Open the lid and drop 1 ml of sample onto the center of the Compact Dry plate.
2. The sample automatically and evenly diffuses into the pad, converting the dry pad into a gel within a few seconds.
3. Replace the lid on the plate and write the required information in the memo section.
4. Invert the covered plate and place it in the incubator. 5. After incubation, count the number of colored colonies under the plate. Placing white paper under the plate helps in counting the colonies.

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *