Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without Guessing

Incubox HyServe Hycubate: When Your HACCP Plan Requires Bacterial Culturing But You Don’t Have Room for a Full Incubator

Published July 10, 2026 at 01:53

On the evening after service, the head waiter wipes two work surfaces with sterile cotton swabs, applies each swab to its own Compact Dry plate, and leaves the plates on the shelf behind the register. The next morning, the environmental health authority inspects the kitchen and asks to see the hygiene follow-up records. The plates show nothing — no colonies at all. Excellent hygiene? No. What was missing was the incubation.

Bacterial colonies do not grow spontaneously at room temperature. They need 24-48 hours at 30-42 °C to multiply enough to be visible to the naked eye. Without an incubator, you can take samples, but you can never read them. This is the structural gap in the small-lab equipment chain that the Incubox HyServe Hycubate fills.

What Compact Dry plates actually are

Compact Dry (Nissui, Japan) is one of the most widely used microbiological culture systems for HACCP and in-house quality control. A plate is a 55 mm round cellulose-based disc with:

  • Colored indicator substances for specific bacteria types (Total Aerobic Count TC, E.coli EC, Salmonella SL, Listeria LM, Staphylococcus X-SA, etc.).
  • A cold-dry nutrient gel surface that is activated when a wet sample is applied.
  • A protective lid that acts as a moisture barrier.

After the sample is applied (100 μl of liquid or a moist swab), the liquid spreads across the gel surface and the bacteria in the sample begin to divide. Each bacterium grows into a visible colony in 12-72 hours, depending on the type.

According to the Compact Dry TC method, the reading is taken after 48 hours at 35 °C. Other tests have different time and temperature requirements: E.coli EC 24 hours at 35 °C, Listeria LM 48 hours at 37 °C, Salmonella SL 24 hours at 41.5 °C.

Why 35 °C, not room temperature

Each type of bacteria has its own optimal temperature for growth rate. For human pathogens (the most relevant for food safety), the optimal temperature is typically 35-42 °C — matching human body temperature, since that is where they evolved to live.

At 20 °C (room temperature), E.coli multiplies with a doubling time of ~2 hours. At 35 °C, this drops to ~20 minutes. The difference over 24 hours: a 4,000× larger colony size. That is why incubation is mandatory — the colonies must be large enough to be counted.

Some bacteria have a lower optimum: lactic acid bacteria thrive at 25-30 °C. For these, incubation is often run at 30 °C. The Incubox has adjustable temperature up to 42 °C, which covers that entire spectrum.

The size gap in the incubator market

Incubators come in three typical size categories:

  • Full lab (60-200 l internal volume): SEK 15,000-40,000. Floor-standing or large benchtop model. Fits 500+ plates.
  • Compact lab (20-40 l): SEK 8,000-15,000. Benchtop model. Fits 100-200 plates.
  • Micro incubator (3-5 l): SEK 3,000-6,000. Portable. Fits 20-60 plates.

The Incubox falls into the micro category, with a usable interior of 21 × 14.5 × 11 cm (approx. 3.4 liters). That is enough for:

  • 60 Food Stamp plates (RODAC 55 mm plates for surface sampling), or
  • 50 Compact Dry plates stacked in groups of 5, or
  • 8 Ø90 mm Petri dishes, or
  • 6 blood culture bottles.

For a small restaurant kitchen taking 5-10 hygiene samples per week, this is sufficient. For a mid-sized food company running 50+ samples per week, a compact-lab size is needed.

Incubox technical specifications

  • External dimensions: 30 × 17 × 15 cm.
  • Usable interior space: 21 × 14.5 × 11 cm.
  • Weight: 1.3 kg.
  • Voltage: 230 VAC (European standard).
  • Heating power: 30 W.
  • Rated current: 0.14 A at 220 V.
  • Preset temperature: 35 °C ±2 °C.
  • Adjustable range: up to approx. 42 °C.
  • Heat-up time from cold start to 35 °C: 20-30 minutes (depending on room temperature and number of plates inside).
  • Control thermometer: digital, integrated.
  • Thermostat: upgraded from the previous model.
  • 2 indicator lights: one for mains power, one for active heating.
  • Warranty: 12 months.

Incubox HyServe Hycubate incubator for Compact Dry SEK 4,450

Transparent door — more than just design

The clear-glass door (clear acrylic) is not cosmetic. In microbiological incubators, the door is opened every time you check how the culture is growing, and each opening lets out heat and requires 5-15 minutes for the temperature to stabilize again.

A clear door means the operator can visually check colony size and distribution without opening it. This is particularly important during the 20-24 hour period, when the colonies are at their most sensitive growth stage — even a 30-second door opening can delay the reading time by several hours.

The scratch- and fingerprint-resistant door coating (a special coating according to the manufacturer) is also practical: a scratched door becomes unusable after 3-6 months of use, and the operator can no longer see inside properly.

Who needs an Incubox

Restaurant kitchens and institutional catering with their own HACCP plan: 3-10 samples per week. The Incubox is sufficient.

Small delicatessen, bakery and dairy businesses: 5-15 samples per week. The Incubox is sufficient.

Waterworks with their own sampling: Compact Dry plates for coliform testing of drinking water. 5-10 samples per week.

Schools and care homes with in-house quality control: 2-5 samples per week. The Incubox is usually sufficient.

Field consultants for hygiene inspection: The portable size and 30 W power consumption make the Incubox useful even for temporary assignments where no lab room is available.

When the Incubox is NOT enough

Mid-sized food companies (50+ samples/week): 50 plates per batch is not enough. Upgrade to a 30-liter benchtop model.

Multi-parameter testing: If different samples require different temperatures (TC at 35, LM at 37, SL at 41.5) at the same time, you need several Incubox units or a dual-zone incubator.

Precision quantitative microbiology: The Incubox has ±2 °C stability. For research purposes requiring ±0.5 °C, a lab incubator with active air circulation is needed.

Cold culturing (lactic acid bacteria at 5-15 °C): The Incubox is heating only, with no cooling function.

Electricity and operating cost

30 W heating power means the Incubox draws a maximum of 30 W during active heating. At a stable 35 °C (after the heat-up phase), the heater cycles on and off, with an average consumption of approx. 5-10 W depending on room temperature and insulation quality.

Operating cost over 24 hours: ~0.2 kWh × SEK 1.5/kWh = SEK 0.30 per incubation. Over a year of continuous operation: ~1,500 kWh × 1.5 = ~SEK 2,250. In practice, the incubator is used 30-40% of the time = ~SEK 700-900 per year in electricity.

What you get for your money

Incubox HyServe Hycubate incubator, usable interior space 21 × 14.5 × 11 cm, room for approx. 50-60 Compact Dry or Food Stamp plates, digital thermometer with upgraded thermostat, preset 35 °C ±2 °C, adjustable up to 42 °C, transparent door for visual inspection without heat loss, 230 VAC 30 W, 1.3 kg total weight, vertical or horizontal placement, can be wall-mounted. Perforated shelf as an accessory. 12-month warranty. SEK 4,450.

It fills the structural gap between NO incubation being done (expensive lab equipment is lacking) and FULL lab incubation (too expensive for a small business). For restaurant kitchens, micro-bakeries, micro-dairies, schools and other small operations that are subject to HACCP requirements, this is one of the most strategic investments for making in-house quality control VERIFIABLE instead of symbolic.

Read more: Incubox HyServe Hycubate incubator in the shop →