Hoppa till innehåll
Free shipping over 5.552 SEK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without GuessingVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsHow to Measure Small, Hot Surfaces from a Safe Distance Without Guessing

Kikkoman Allergen ELISA II Kit for Egg Protein (Ovalbumin), 96 Determinations: Quantify 0.5 ppm When Lateral Flow Can Only Say ”Yes or No”

Published July 9, 2026 at 11:53

Two methods to detect allergen protein in food. Both rely on antibody-specific binding — the same fundamental immunological principle as Lateral Flow rapid tests. But ELISA (Enzyme-Linked Immunosorbent Assay) provides a completely different type of result: a quantitative concentration expressed in mg protein per kg food, with a detection limit typically of 0.5-1 ppm. For certain allergen verification scenarios, this quantitative value is NOT optional — it’s a regulatory requirement.

ELISA vs. Lateral Flow — data quality

The Lateral Flow rapid test gives a visual yes/no reading: a line appears, the sample contains allergen; no line, no allergen. Detection limit typically 1-10 ppm. Total measurement time 45 minutes. No lab equipment needed.

The ELISA method provides a numerical concentration:

  • Quantifies from the detection limit (~0.5 ppm for ovalbumin) up to ~200 ppm.
  • Total measurement time 3-4 hours for a 96-well plate (can run 88 samples in parallel).
  • Requires lab equipment: microplate reader, incubator, precision pipettes, vortex mixer.
  • Data in mg protein per kg food — directly comparable between different samples and over time.

Choice: Lateral Flow for field use and quick QC; ELISA for formal documentation and batch release testing.

What ELISA actually does chemically

ELISA uses a ”sandwich” protocol (also called capture ELISA):

  1. The plate’s wells are coated with a ”capture antibody” that binds specifically to the target protein (ovalbumin in the case of egg). These antibodies are factory-pre-coated on the plate.
  2. Sample is added: 100 µL of extracted food sample per well. If ovalbumin is present in the sample, it binds to the capture antibodies. Samples without ovalbumin bind nothing.
  3. Wash: Unbound material is rinsed away.
  4. ”Detection antibody”: Another antibody that also binds to ovalbumin (at a different epitope) is added. This antibody is conjugated to an enzyme (typically horseradish peroxidase, HRP).
  5. Wash again: Unbound detection antibody is rinsed away.
  6. Substrate: HRP substrate (TMB, tetramethylbenzidine) is added. HRP catalyzes the reaction and a color develops (blue turning yellow when stopped with acid).
  7. Reading: A microplate reader measures optical density at 450 nm. Color intensity is proportional to the amount of target protein.
  8. Calibration: A standard curve is built from known concentrations of ovalbumin (typically 0, 1, 5, 20, 100 ppm). The unknown sample is compared against the curve to obtain the concentration.

Why egg protein is critical

Egg is one of the EU’s 14 major allergenic ingredients (EU Regulation 1169/2011). Symptoms of egg allergy can range from mild skin reactions to anaphylactic shock. Egg allergy in children is common — approximately 1-2% of infants develop it, and while most outgrow it before school age, 15-20% of adults with confirmed egg allergy remain allergic for life.

Ovalbumin is the main protein in egg white (54% of protein content). Other allergenic egg proteins include ovomucoid and ovotransferrin. The ELISA test is specific to ovalbumin, but since it’s the dominant protein, this is practically sufficient for allergen detection.

Where quantitative data is really needed

Batch release testing: EU food producers wanting to certify products as ”egg-free” must document concentrations below the detection limit. A concentration below 0.5 ppm enables ”egg-free” labeling; above the limit requires declaration.

PAL decisions (Precautionary Allergen Labeling): When cross-contamination is possible from the production environment, the producer must decide whether a ”may contain egg” warning should be placed on the packaging. The decision is based on quantitative measurements, NOT yes/no tests.

Complaint investigations: When a consumer complains of symptoms after eating a product, the presence of egg in the batch is investigated. A quantitative value is important to confirm or rule this out.

Regulatory audits: FDA, EFSA, DAkkS-accredited auditors require quantitative documentation in certain cases.

Research studies: Egg allergy threshold research requires precisely quantified concentrations.

Kikkoman Allergen ELISA II Kit for egg (ovalbumin), 96 determinations

Practical workflow

The ELISA workflow consists of two main phases:

Sample preparation (30-60 minutes): Homogenization of the food sample, extraction with buffers, filtration. This step is the same as for Lateral Flow — the new ”extraction solution” included with the Kikkoman ELISA II is improved over the previous generation for higher recovery from processed foods.

ELISA analysis (2-3 hours): Pipetting sequence of sample + standard series on the 96-well plate, incubations with washing between each step, final reading. This is routine lab work and requires training but can be performed by technically trained personnel.

Total time: 3-4 hours from sample to final result. A 96-well plate has wells for 88 samples + 8 wells for the standard series (0, 1, 5, 10, 20, 50, 100, 200 ppm ovalbumin). Batch operation is cost-effective.

Detection limit and sensitivity

The Kikkoman ELISA II Kit has an LOD (Limit of Detection) of 0.31 ppm and an LOQ (Limit of Quantification) of 0.63 ppm for ovalbumin. This is very low — meaning that a product with 0.5 ppm ovalbumin can be detected and quantified.

Practical context: a whole-grain product with 0.5 ppm ovalbumin contains approximately 0.5 mg protein per kg product. An allergic person consuming 200 g of the product would then get 0.1 mg ovalbumin — which is below most reaction thresholds but NOT below all of them. A quantitative value enables risk assessment at the individual level.

Calibration curve and quality control

The standard curve is built using known concentrations supplied in the kit. Each plate run includes its own standard — which compensates for plate-to-plate variation and time-dependent reagent degradation.

Quality controls: the kit’s internal positive and negative control samples should give expected values within specified tolerances. If QC values fall outside the limit, the entire run is discarded and a new plate is run.

AOAC RI approval for the Kikkoman ELISA II for ovalbumin confirms the method’s reliability according to international standards.

What you get for your money

Kikkoman Allergen ELISA II Kit for egg protein (ovalbumin), 96 wells per plate (capacity for 88 samples + standard series), sandwich ELISA protocol, LOD 0.31 ppm / LOQ 0.63 ppm, microplate reader compatible (450 nm), included extraction solution for improved recovery from processed foods, AOAC RI-approved method, 18-month shelf life at 2-8 °C.

7,617 SEK per kit = ~87 SEK per test. Compared to Lateral Flow (~208 SEK per test), ELISA is cheaper per test — but requires lab equipment (microplate reader ~20,000-50,000 SEK, incubator, pipettes) which represents fixed costs. For food QC labs with regular testing volume (>500 tests per year), the investment pays off immediately. For ad-hoc testing, Lateral Flow is the economical choice.

Read more: Kikkoman Allergen ELISA II Kit for egg in the shop →

More news