Published 4 July 2026 at 21:37
Legionella bacteria live in water and cause thousands of cases of Legionnaires’ disease in Europe every year. What few property owners know is that the bacteria don’t need special conditions. A hot water system with poor temperature control is enough. In Sweden and the EU, the employer’s responsibility is governed by local regulations that all say essentially the same thing: cold water must stay below 20 °C, and hot water must stay above 60 °C in the calorifier and above 50 °C at every tap. Legionella grows best between 20 and 45 °C, and the risk assessment must verify that the system avoids this window.
What the kit contains
The ETI Thermometer Kit for Legionella Checks is a complete field kit packed in a rugged ABS case. Contents:
- Therma® Waterproof thermometer with IP66/67 protection, 0.1 °C resolution and an LCD display.
- Immersion probe for measuring cold and hot water temperature at the outlet (tap, shower, point of use).
- Surface probe for measuring pipe and tank surfaces without opening the system.
- Wire probe for reaching into narrow or deep pockets that other probes can’t access.
- Waterproof timer for measuring hot water stabilization times and flushing cycles.
- 100 probe wipes for hygienic disinfection between measurement points, preventing cross-contamination between areas.
- Traceable calibration certificate, documenting that the instrument gives accurate readings.
Why you need three probe types
A risk assessment under ACOP L8 (the UK Approved Code of Practice, which Swedish property managers effectively follow) requires measurements at several different points in the water system:
Immersion probe: the water itself. At the tap and shower outlet, the actual water temperature is measured by immersing the probe to a depth of at least 25 mm. Here the hot water should reach above 50 °C within 1 minute of opening the tap, and the cold water should be below 20 °C. An immersion probe in the outflow is the only way to verify this correctly.
Surface probe: the circulation system’s pipes. Pipe surfaces in the circulation loop are measured on the outside (without opening the system) to check that the hot water circulation holds its temperature throughout. Cold spots in the loop reveal dead legs or insulation faults that create Legionella pockets.
Wire probe: inaccessible pockets. In the hot and cold water calorifiers, the water temperature is measured at the bottom and the top. The bottom layer is typically colder and can end up in the danger zone even if the outlet temperature is correct. This calls for a thin wire probe that can be threaded in through a sampling valve or an air vent.
Without all three probe types, the risk assessment is incomplete and the documentation is not sufficient to meet the employer’s responsibility.
Why 0.1 °C resolution matters
Legionella checks are made at critical temperature thresholds: 20 °C, 45 °C, 50 °C and 60 °C. An analog thermometer with a 1 °C scale produces readings of ”about 50” or ”about 60”, which is inadequate when the ACOP specifies exact limits. With 0.1 °C resolution, you can document 50.3 °C versus 49.7 °C and clearly show whether the limit has been met.
This is especially important for catching marginal installations, where the system works but only just. A calorifier holding 61.2 °C passes, but it is one faulty sensor away from dropping below 60 °C. Such installations can only be found with high resolution.
IP66/67 protection: why it matters
Legionella inspections take place in wet locations: bathrooms, basements and plant rooms. The instruments are exposed to splashes, condensation and sometimes outright immersion. The IP66/67 rating means the thermometer can withstand:
- IP66: Fully dust-tight and resistant to powerful water jets from all angles.
- IP67: Resistant to immersion in up to 1 meter of water for 30 minutes.
Standard thermometers without this protection can behave erratically after a single splash accident. IP66/67 ensures the instrument holds up to daily fieldwork.
Probe wipes: hygiene between measurement points
Legionella checks mean using the same probes at many different points of use in the same building. Without hygienic cleaning between measurement points, a probe can carry bacteria from a contaminated area to a clean one, which can distort the next analysis or even spread bacteria. The kit includes 100 probe wipes with an antibacterial formulation to disinfect the probe between each measurement. This is standard procedure in professional inspections.
Where the kit makes a real difference
Residential property management: Annual or semi-annual checks of all hot and cold water systems in line with the guidelines of Boverket and the Public Health Agency of Sweden. One kit is enough for hundreds of measurement points per year.
Hotels and conference facilities: Rarely used guest rooms have stagnant water in the pipework, and Legionella pockets can form. Regular checks are part of quality management.
Hospitals, care homes and nursing homes: Immunosuppressed people are especially susceptible to Legionella. Monthly checks are required here under the guidance of the Swedish National Board of Health and Welfare (Socialstyrelsen).
Gym chains and swimming pools: Showers with hot water are classic Legionella sources. The combination of aerosol, warm water and users with potentially weakened immune systems is a high risk factor.
Industrial and production premises: The employer’s responsibility applies to all premises regardless of size. Offices with coffee machine systems and toilets also need to be verified.
Consulting and inspection companies: Legionella consultants who carry out third-party risk assessments. The instrument is an everyday tool for professionals in the field.
Plumbing installers and service engineers: During new installations and service visits, a quick test can confirm that the system meets the temperature requirements right at handover.
Municipal property companies: Schools, preschools and swimming pools. The municipality’s duty of care toward pupils and visitors requires documented checks.
What you get for your money
ETI Thermometer Kit for Legionella Checks, with Therma® Waterproof thermometer (IP66/67, 0.1 °C resolution), immersion, surface and wire probes, waterproof timer, 100 probe wipes for hygiene, ABS carry case, and traceable calibration certificate.
At SEK 3,564, this is an investment that pays for itself immediately, since you no longer need a calibration service for each probe, you can document your risk assessments, and you can carry out the checks in-house instead of hiring an external consultant (typically SEK 5,000–15,000 per inspection). For property companies with several sites, the kit pays for itself after the first inspection. Combined with proper record-keeping, it meets both Swedish legislation and EU recommendations.