ETI Thermometer kit for legionella water temperature checks. Includes Therma® Waterproof thermometer, penetration probe, surface probe, wire probe, timer, etc.
4.362 SEK
Waterproof thermometer kit designed for Legionella risk assessments
0.1 °C resolution
3 probe types included
IP66/67 waterproof protection
Free calibration certificate
Water-resistant timer
Box of 100 single-sachet probe wipes
ABS carrying case
Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%
- Free shipping on orders over 3000 SEK excl. VAT
- Measuring instruments and hygiene tests for self-monitoring since 2003
- Call us +46 8 753 00 04
Other models in the series 16
Description
Waterproof Legionnaires’ thermometer kit or Legionella thermometer kit with IP66/67 Therma Waterproof thermometer.
This waterproof Legionella testing thermometer kit can be used to monitor the temperature of both standing water and the surface of pipes and tanks that are part of the water system. The penetration probe can also be used to test the temperature of tap water.
The immersion probe should be placed in the water to a minimum depth of 25 mm. The ribbon surface probe can be used to take the temperature of pipes and tanks, and the wire probe can be used to reach awkward places or where the other probes are not suitable. This kit is supplied with a traceable calibration certificate.
Incorrect water temperature is a key risk factor for Legionella growth. Legionella bacteria multiply in water at temperatures between 20 and 45 °C, especially if there is a supply of nutrients, such as scale, rust, sludge, or algae. A typical control method is to store cold water below 20 °C. Hot water should be stored above 60 °C and distributed at above 50 °C.
Current legislation means that if you are an employer or a person in control of premises, you must carry out a risk assessment. The revised Approved Code of Practice (ACOP) issued by the government’s Health and Safety Executive (HSE) significantly extends the scope of its guidance on the control of Legionella bacteria in water.
The code now applies to all hot and cold water systems in the workplace, regardless of their capacity, i.e. the lower limit of 300 litres previously used to exclude domestic systems no longer applies. Although domestic systems can present a risk, the code applies only to risks arising from a work activity.
This means that all employers managing premises with hot/cold water systems and/or a wet cooling system have a legal duty to identify any risk of contamination and to prevent or control it.
Each waterproof Legionella thermometer kit contains:
1 x Therma Waterproof thermometer (17-232101)
1 x Waterproof penetration probe (17-143162)
1 x Precision ribbon surface probe (17-123030)
1 x PTFE wire probe (17-133362)
1 x countdown timer (17-806150)
1 x box of 100 single-sachet Probe Wipes (17-836220)
1 x ABS carrying case (17-834150)
For full information on the Therma Waterproof thermometer, click here.
Dimensions: Instrument: 32 x 71 x 141 mm, Case: 220 x 265 x 75 mm
LEGAL DUTY TO TEST FOR LEGIONELLA
If you are an employer or a person in control of premises, you must organise a risk assessment for exposure to Legionella. The revised Approved Code of Practice (ACOP) Legionnaires’ disease: The control of legionella bacteria in water systems (L8) issued by the government’s Health and Safety Executive (HSE) significantly extends the scope of its guidance on the control of Legionella bacteria in water. The code applies to all hot and cold water systems in the workplace, regardless of capacity, i.e. the lower limit of 300 litres previously used to exclude domestic systems no longer applies. Although domestic systems can present a risk, the code applies only to risks arising from a work activity, but includes domestic landlords who have a duty to keep their tenants safe from health hazards. This means that all employers and landlords who manage premises with hot/cold water systems and/or wet cooling systems have a legal duty to identify any risk of contamination and to prevent or control it.
Specifications
| Measuring range: | -99.9 to 299.9 °C (at 0.1 °C), 300 to 1372 °C (at 1 °C) |
|---|---|
| Range 0.1 °C: | -99.9 to 299.9 °C |
| Range 1 °C: | 300 to 1372 °C |
| Max/Min: | Yes |
| Resolution: | 0.1 °C to 299.9 °C thereafter 1 °C |
| Accuracy – Instrument only: | ±0.4 °C ±0.1% of reading |
| Battery: | 3 x 1.5 volt AAA |
| Battery life: | minimum 5 years (10,000 hours) |
| Sensor type: | K-Type Thermocouple |
| Display: | 15 mm LCD |
| Backlight: | Yes |
| Dimensions: | Instrument: 32 x 71 x 141 mm, Case: 220 x 265 x 75 mm |
| Weight: | 220 grams |
| Case material: | ABS plastic contains Biomaster product protection |
| Country of manufacture: | United Kingdom |
| Warranty: | two years |
| Water/dust resistance: | IP66/67 protection |
| Measurement scale: | Celsius |
| Certification: | FREE traceable calibration certificate |
| Conforms to standard: | EN 13485 |
Additional information
| Product Type | Digitalt Termometer-Kit |
|---|---|
| Specifikation | Insticksgivare |