Published 20 November 2026 at 02:01
You’re standing at a radiator that isn’t heating the way it should. With one thermometer you measure the supply line, then go to the return with the same thermometer and try to remember the number from the previous measurement. In the meantime the system has had time to change, and the difference you’re looking for has been calculated in your head rather than measured. It’s a common way of working, and a common way of drawing the wrong conclusion.
What is a differential thermometer?
The ETI Therma Differential is a digital two-channel thermometer for type K thermocouples. You connect two probes and choose on the display whether you want to see T1, T2 or the difference T1-T2. The measuring range is -99.9 to 299.9 °C with a resolution of 0.1 °C, and up to 1372 °C with a resolution of 1 °C. The accuracy is ±0.4 °C ±0.1% of the reading. The instrument has max, min and hold functions as well as an illuminated display.
What problem does it solve?
Many faults in heating, cooling and process systems are not visible in a single temperature but in the difference between two points. With two probes at the same time, you measure both values at the same instant, and the instrument calculates the difference for you. You avoid both time lag and mental arithmetic. The max and min values also show how the system behaves over a longer period, not just at a single reading.
Three typical areas of use
Heating and plumbing. When balancing radiators and underfloor heating, you measure the temperature drop between supply and return. If the drop is too small, the flow is too high; if it is too large, the radiator gets too little water. The same method works for checking circulation in hot water systems.
Ventilation and cooling. The difference between supply and extract air, or between the refrigerant inlet and outlet, shows whether a heat exchanger or cooling coil is performing as intended.
Food production and industry. When cooling tanks, pasteurizing or running dishwashers, you can compare the temperature before and after a process and document that the step is doing its job. The housing is waterproof to IP66/67, which withstands a damp and splash-prone environment.
Why it pays off
Time is the clearest gain. A balancing job that would otherwise require several trips between measuring points can be done in one go with the probes in place. It also reduces the risk of systems being left poorly balanced, which would otherwise lead to complaints, return visits and unnecessary energy consumption. The instrument is powered by three AAA batteries with a battery life of 7,500 hours and switches off automatically after about ten minutes, so running costs are minimal.
Please note that the thermometer is sold without probes. Choose the probes that suit your application, for example surface probes for pipes or immersion probes for liquids, and add them as accessories.
If you need to measure temperature drops, differences between supply and return, or the effect of an adjustment, a differential thermometer is a simple and reliable tool.