Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Air temperature in the fridge doesn’t tell you how warm the product isThe fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspectionsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Air temperature in the fridge doesn’t tell you how warm the product isThe fridge failed on Friday evening and no one noticed until Monday morningLegionella control that doesn’t end up in a binder: timestamped temperatures straight from the tapMoisture that isn’t visible on the surface becomes most expensive when it’s discovered after the floor is laidA Surface That Looks Clean Can Still Be Dirty: How ATP Measurement Shows the Result in Ten SecondsStop guessing the salt in your brine: read the concentration in a few secondsThree known temperature points are enough to tell whether your thermometer still reads correctlyHow to Know Your Thermometer Still Reads Correctly: Checking Type K Instruments at Three Known PointsOne drop is enough to see whether the coolant concentration is correct, without interpreting a borderline by eyeA spot check doesn’t tell you what happened in the cold room overnight between two inspections

How to Measure pH in Sushi Rice

Published April 30, 2020 at 6:56 PM

How to check and measure the pH / acidity of sushi rice.

  1. Weigh out the sushi rice and distilled (deionized) water on a scale so that you have 1 part sushi rice to 9 parts distilled water.
  2. Pour everything into a clean glass beaker that has been rinsed beforehand with distilled water. Wait until the temperature is close to room temperature.
  3. Stir gently with a clean spoon until the rice has completely dissolved in the distilled water.
  4. Calibrate the pH meter according to the manufacturer’s specifications.
  5. Gently rinse the pH probe with distilled water and dry it with clean paper.
  6. Immerse the pH probe so that the sensing element is fully submerged, and wait until the pH value on the pH meter has stabilized. Gently stir with the probe if desired.
  7. Read off and record the pH value. The reading must be no higher than pH 4.5.

ALWAYS perform a calibration before each series of measurements on sushi rice. Use only distilled water for cleaning before the measurement. Store the equipment according to the manufacturer’s recommendations.