Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The Floor Was Laid on Concrete That Looked Dry, but the Moisture Meter Had Said OtherwiseHow to check your thermocouple thermometer yourself without an ice bath or dry blockAir in the fridge responds in minutes, food in hours – so measure with a probe that behaves like the foodCarbon dioxide levels show whether ventilation is working, something temperature never revealsWhen the temperature is read in 0.4 seconds, checking becomes routine rather than an interruptionThe temperature was right at the check, but what happened at three in the morning?A clogged filter first shows up as a pressure drop, but only if you measure across itOne Drop Is Enough: How to Check Sugar Content and Cutting Fluid Concentration in SecondsHow to know your thermometer reads correctly: check your instruments yourself between -10 and 110 °CThe surface shows one temperature, the core another: why you need both IR and a penetration probeVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The Floor Was Laid on Concrete That Looked Dry, but the Moisture Meter Had Said OtherwiseHow to check your thermocouple thermometer yourself without an ice bath or dry blockAir in the fridge responds in minutes, food in hours – so measure with a probe that behaves like the foodCarbon dioxide levels show whether ventilation is working, something temperature never revealsWhen the temperature is read in 0.4 seconds, checking becomes routine rather than an interruptionThe temperature was right at the check, but what happened at three in the morning?A clogged filter first shows up as a pressure drop, but only if you measure across itOne Drop Is Enough: How to Check Sugar Content and Cutting Fluid Concentration in SecondsHow to know your thermometer reads correctly: check your instruments yourself between -10 and 110 °CThe surface shows one temperature, the core another: why you need both IR and a penetration probe

How to check your thermocouple thermometer yourself without an ice bath or dry block

Published 28 November 2026 at 03:37

The thermometer sits in the toolbox, the display shows a number and everyone trusts it. As soon as someone asks when it was last checked, it goes quiet. This is a common situation in workshops, production lines and kitchens, and it only becomes uncomfortable when an auditor, a customer or a deviation demands an answer. Often the instrument is then sent away for external calibration and is gone for weeks, or an ice bath check is set up that nobody really has time for.

ETI MicroCal® 3 kalibrerad temperatursimulator, simulerar temperaturgivare typ K med 23 st olika temperaturer. Med kalibreringscertifikat

What MicroCal 3 is

MicroCal 3 is a handheld temperature simulator for type K thermocouples. Instead of heating or cooling anything, it sends out the signal that a type K thermocouple would produce at a selected temperature. You connect the thermometer, select one of 23 fixed points between -100 and 1200 °C, and compare what the thermometer shows with the value the simulator indicates. No conversion tables are needed.

The instrument has an alphanumeric display that guides you through the settings: °C or °F, automatic shut-off, and internal or external cold junction compensation (CJC). The accuracy is ±0.5 °C. It comes with a one-metre cable with a miniature connector and a five-point UKAS certificate showing the simulator’s own deviations. The instrument is thus traceable in its own right.

What problem it solves

Measurement errors in the electronics, such as drift or an incorrectly set instrument, are rarely discovered in everyday use. MicroCal 3 means a check takes a few minutes and does not require a temperature source that has to stabilise. It is possible to check often, and it is the frequency that makes self-inspection credible. Note that the simulator checks the instrument, not the probe itself. The condition of the probe is assessed separately, for example with a comparison measurement at a known reference point.

Three practical uses

Manufacturing industry. In hardening, furnace checks and heat treatment, temperature governs the properties of the material. Points such as 300, 600 and 1000 °C make it possible to check handheld and benchtop instruments at the levels where the process actually operates.

Food production. Cold-holding and hot-holding checks are part of HACCP work. The points at -20, 0, 60 and 100 °C cover freezing, chilling, hot holding and cooking. The check can be documented in the same routine as other self-inspection.

Maintenance and HVAC. Service technicians who measure on heating systems, furnaces and process equipment can check their thermometer before the work starts, instead of suspecting it afterwards when the numbers do not add up.

Why it pays off

The cost of an instrument that reads incorrectly is rarely the thermometer itself. It lies in a scrapped batch, a rerun or a certificate that does not hold up. With your own simulator, instruments do not have to leave the building for every check, and only those that deviate need to be sent for full calibration. This reduces downtime and gives more consistent documentation. For a business with several thermometers, one simulator is often enough for the whole fleet.

If you want to make temperature checking a routine rather than an exception, MicroCal 3 with certificate is available from us. See the product here.